· Material …………………………………… Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) · Expected life ……………………………… See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60˚C, rated voltage) Expected life at 40°C is for reference only. · Motor protection function ……………… Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 573. · Dielectric strength ……………………… 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) · Insulation resistance …………………… 10 MΩ or more with a 500 VDC megger (between lead wire conductors and frame) · Sound pressure level (SPL) …………… At 1 m away from the air inlet · Storage temperature …………………… -30 to +70˚C (Non-condensing) · Lead wire ………………………………… Red Black Sensor Yellow Control Brown · Mass ……………………………………… 270 g